8 www.infectioncontroltoday.com ICT August 2018 SPD dialogue Q RN, AAS, ACSP, CSPM, CRER By Nancy Chobin Ò Holding Manufacturers Accountable for Their IFUs Medical device manufacturers are responsible for providing clear written instructions on handling, cleaning, disinfection, testing, packaging, sterilization and aeration. Q: If an end user fi nds that the manufacturer's instructions for use (IFUs) are vague and not detailed enough and there is not an update/ revision available, can this be reported via the Food and Drug Administration (FDA) Medwatch program, so that the manufacturers can update their IFUs so that they are comprehendible? Or is there another means by which to handle this? If the IFUs aren't clear and the manufacturer cannot provide more clarifi cation immediately for a reprocessable item, do you halt the process and take the item out of use until you can get clarifi cation on the care/cleaning/sterilization IFU? A: The sophistication of medical/surgical procedures has resulted in new generation of instruments and medical devices. These devices can vary in size, weight, complexity and immersibility. In addition, they can vary in cleaning, disinfecting and sterilization processes. The Joint Commission (2014) addressed improperly sterilized or high-level disinfected (HLD) equipment in Quick Safety Issue 2. Three years later, improperly sterilized or HLD equipment continues to be a frequently scored noncompliant standard — Infection Control (IC) 02.02.01. "The Joint Commission encourages leadership to carefully oversee these processes and ensure that staff is properly trained and has the resources needed to adequately perform these critical functions." The Joint Commission Standard IC.02.02.01 requires organizations to reduce the risk of infections associated with medical equipment, devices and supplies. This standard is applicable to Joint Commission-accredited hospitals (HAP), critical access hospitals (CAH), ambulatory (AHC), and offi ce-based surgery (OBS) facilities. Of these, the most vulnerable locations for lapses in sterilization or HLD of equipment are 1) ambulatory care sites (including offi ce-based surgery facilities) and 2) decentralized locations in hospitals, even though the data shows higher noncompliance rates for critical-access hospitals and hospitals. The Joint Commission standard IC.02.02.01 states that, "The [organization] reduces the risk of infections associated with medical equipment, devices, and supplies.) was one of the top requirements cited most frequently as 'not compliant' during surveys and reviews of ambulatory care facilities, hospitals and offi ce-based surgery practices for the fi rst half of 2016." The non-compliance rates (2016): • For ambulatory care, this standard was the most challenging requirement, with 49 percent non-compliance. • For hospitals, it was the second most challenging, with 59 percent non-compliance. • For critical-access hospitals, it was tied for the most challenging, with 73 percent non-compliance. • For offi ce-based surgery practices, it was the second most challenging, with 53 percent non-compliance . So, what are the consequences? The consequences of failed processes can result in one or more of the following: • Placing patients at risk for contamination • Causing potential outbreaks • Potential loss of Joint Commission accreditation • Potential loss of Centers for Medicare and Medicaid Services (CMS) deeming status • Bad publicity, lost business and a damaged reputation • Litigation The Joint Commission has found that from 2013 to 2016, immediate threat to life (ITL) declarations directly related to improperly sterilized or HLD equipment increased significantly. In 2016, 74 percent of all immediate threat to life declarations were related to improperly sterilized or HLD equipment. What helpful resources exist? AAMI has a document, AAMI TIR-12, "Designing, testing, and labeling reusable medical devices for reprocessing in health care facilities: A guide for medical device manufacturers." This document was originally published in 2005 and was updated in 2010; it is currently being updated again. While not a national standard, this document does address all the design considerations to make sure products can be safely and effectively reprocessed in healthcare facilities. In this document, it states that, "Medical device manufacturers are responsible for providing clear written instructions on handling, cleaning, disinfection, testing, packaging, sterilization and aeration. The manufacturers must also test to validate their claims and instructions they provide. In addition, healthcare personnel need to verify manufacturers' data and instructions, and have resources to follow them through." Your facility should have a policy, supported by administration, that: • devices will not be purchased unless the IFU has been reviewed and that the IFU can be duplicated, exactly as written, at your facility. • ensures all instructions followed correctly by staff For new devices, an in-service should be scheduled with the device manufacturer's representative. The in-service should be on-site, include hands-on training, a return demonstration and competency verifi cation

Articles in this issue

Links on this page

Archives of this issue

view archives of Infection Control Today - AUG 2018